ID on the target lift is set using jumpers on the target lift card. See the document ML2000Man02EN-Installation for more information.
Edited: 2018-10-05  Link: https://www.megalink.no/login/?page=faq&lang=en#how-to-set-id-on-target-liftSomethimes an error in the system sets the motor length for the band advance to zero. To avoid this we recommend to power on the targets first, then power on the monitors.
Edited: 2017-06-26  Link: https://www.megalink.no/login/?page=faq&lang=en#band-advance-length-is-zeroIn MLRange goto Menu -> Setup -> Targets.
Edited: 2019-01-11  Link: https://www.megalink.no/login/?page=faq&lang=en#how-to-get-maintenance-warning-after-x-shots-on-targetNB: Use Chrome, certain browsers give wrong values. Does not work with CU 18.37/18.38, use CU 18.19.
If the X and Y value of the monitor and the target is not consistent, the target can be calibrated.
This can be done by moving the logical center on the target (Offset).
Use this tool for finding the correct offset:
https://www.megalink.no/login/?page=calibrate
Edited: 2019-04-05  Link: https://www.megalink.no/login/?page=faq&lang=en#how-to-calibrate-my-high-power-targetsA monitor can be connected directly to the 3D-Score 25/50 connection bar for troubleshooting. Only the lastest version of color monitor can be used. Version can be checked on the monitor Systemstatus -> Hardware: DU3 i1.
Edited: 2019-02-06  Link: https://www.megalink.no/login/?page=faq&lang=en#troubleshoot-3d-score-2550-directly-using-monitorDuring normal operation a green diode blinks with a period of a couple of seconds. If the diode blinks rapidly this may indicate too low voltage.
During activity on the communication line a red/orange diode blinks. The frequency is affected by the number of units communicating on the same communcation line.
Two green diodes blink whenever the microphone has detected a sound. One with a short blink and one with a longer blink. (Diodes may be red/orange)
Edited: 2019-02-15  Link: https://www.megalink.no/login/?page=faq&lang=en#led-indicator-on-controller-unit-cu3-hw-version-64-to-newestSeen up front:
3UXXX
A B C
4KXXX
B D
A C
8K000
B B2 D
A2 D2
A C2 C
BIA1200:
U1 U2 U3 U4 D1 B1 D2 B2
=
L1 L2 L3 L4 A1 C1 A2 C2
BIA1200_12
U1 U2 U3 U4 U5 U6 B1 D1 B2 D2 B3 D3
=
L1 L2 L3 L4 L5 L6 A1 C1 A2 C2 A3 C3
Edited: 2021-03-08  Link: https://www.megalink.no/login/?page=faq&lang=en#where-are-the-censors-located
Shot detection in the 3D-Score depends on the IR-diodes and sensors inside the target.
Use the camera on a cell phone to determine that there are IR-light in all the slots inside the target. Please note that only half of the slots contains IR-diodes with light visible on the camera. The other slots contains IR-sensors with no ligth.
On the small 3D-Score you will need to enable the IR-diodes:
1. Unplug the power
2. Press and hold the button on the rear side of the target while reconnection the power
Procedure for factory reset / recovery is changed. Please see the document ML2000 Manual – Display Unit (Monitor) for more information.
Edited: 2016-03-07  Link: https://www.megalink.no/login/?page=faq&lang=en#factory-reset--recovery-monitorThe monitor has start up problems and only the Megalink logo is seen: This can be fixed by using factory restore. See section 4.3 in the User Manual for ML2000 Display Unit. The recovery file can be downloaded from the Software section.
Edited: 2018-10-05  Link: https://www.megalink.no/login/?page=faq&lang=en#monitor-only-shows-megalink-logoSelect Menu → Display Config → Language
or
Select Meny → Skjerm innstill → Språk
Edited: 2016-09-12  Link: https://www.megalink.no/login/?page=faq&lang=en#how-do-i-change-the-language-on-the-monitorWhen the gauge is to small to be visible, an additional colored circle is added to the plot. Se explanation here: Plotting of shots
Edited: 2017-10-17  Link: https://www.megalink.no/login/?page=faq&lang=en#what-is-the-greenred-circle-plotted-on-the-shots
How to remake the secound monitor kit SD card:
1. Download the image file here: www.megalink.no/download/PiSlave2019.6.img
2. Download the Etcher tool from www.etcher.io.
3. Insert the SD card in the SD card slot on your computer.
4. Start Etcher.
5. Select the image file you downloaded.
6. Select the SD card.
7. Press the Flash! Button.
Setting the correct target ID to the new SD card:
1. 1. Download the slave kit ID setting tool: MLSetPiIp
2. 2. Set ID (IP) to the SD Card using MLSetPiIp as described in chapter 1.9 in this document: BRUK-DU-DISPLAY.pdf
Edited: 2021-07-09  Link: https://www.megalink.no/login/?page=faq&lang=en#how-to-remake-the-sd-card-on-the-megalink-second-monitor-kitLED marked USB: The LED is blinking each 5 secound and for each message when connection to MLRange. The connection can be testet by sending a message from MLRange or fetch status.
LED marked LINE/PWR: Lights when the adapter is powered. The LED is blinking when the adapter communicate with monitors/targets.
Edited: 2018-02-05  Link: https://www.megalink.no/login/?page=faq&lang=en#what-is-the-blinking-leds-on-the-usb-adapterIf MLRange do not automaticly connect to the MLLive application you can force MLRange to use the IP address of the MLLive PC.
Example:
[CONFIG]
MLLiveIP=192.168.128.43
NB: Make sure there are no # on the start of the line.
Edited: 2022-06-16  Link: https://www.megalink.no/login/?page=faq&lang=en#mlrange-do-not-connect-to-the-mllive-applicationPlease see the How-To on this page:
http://results.megalink.no/#/howto
Edited: 2016-08-24  Link: https://www.megalink.no/login/?page=faq&lang=en#how-do-i-use-mllivePlease see the list here: http://results.megalink.no/#/howto
Edited: 2016-08-24  Link: https://www.megalink.no/login/?page=faq&lang=en#what-targets-are-supported-by-mlliveAn event with 10 relays, 10 targets and an average of 35 shots per shooter gives an upload of approximately 40 MB.
Edited: 2016-10-11  Link: https://www.megalink.no/login/?page=faq&lang=en#how-much-data-is-uploaded-with-mlliveMLLive must be installed on Windows 7 or newer.
Edited: 2016-12-02  Link: https://www.megalink.no/login/?page=faq&lang=en#what-are-the-requirements-for-running-mlliveHere is how to make an url to selected targets instead of the complete range in MLLive:
1. Go to resultat.megalink.no
2. Select one ore more targets in the same range. The url will be results.megalink.no/#!/event_name/100m/
3. To allways show for instance target 3, 4 and 8 every time you can change the url as follows: results.megalink.no/#!/event_name/100m/100m_3,100m_4,100m_8
4. Save the url as a bookmark.
Edited: 2018-10-05  Link: https://www.megalink.no/login/?page=faq&lang=en#make-an-url-to-selected-targets-in-mllive1. Goto Settings --> Safari --> Clear History and Website data.
2. Reload results.megalink.no
Edited: 2018-01-30  Link: https://www.megalink.no/login/?page=faq&lang=en#names-are-not-showing-or-unreadable-on-iphoneUse Chrome web browser
Edited: 2019-05-10  Link: https://www.megalink.no/login/?page=faq&lang=en#browser-targets-not-loading-only-a-spinning-wheelMLLiveArena is a new and more simple system for audience display. MLLiveArena is working like the MLLive App, but with local storage. Internett is not required.
Edited: 2022-05-12  Link: https://www.megalink.no/login/?page=faq&lang=en#what-is-mllivearena
If MLRange do not automaticly connect to the MLLiveArena application you can force MLRange to use the IP address of the MLLiveArena PC.
Example:
[LiveArena]
ip=192.168.128.43
Please click here:
https://megalink.no/targetlist
Edited: 2023-04-26  Link: https://www.megalink.no/login/?page=faq&lang=en#what-target-fronts-are-supported-in-mllivearenaTo move the average to center press [F12] or select "Ballistic test mode" in the "Ballistic test" menu.
To make a report press [Ctrl] + [P] or select Menu → Print.
It's recommended to use the course of fire "Testing". To show a cross instead of a target select the target named "International Ballistic test".
Tip: In the meny Ballistic test → Ballistic test config the options Name cards and Name series should be selected.
To make MLShoot allways start in ballistic test mode select BTS mode on startup in the config menu.
To remove a shot press [F9] to get the shot details list. Activate or deactivate each shot by cliking on them.
Edited: 2016-09-05  Link: https://www.megalink.no/login/?page=faq&lang=en#how-do-i-remove-shoots-from-the-listSelect Menu → Display Config → Language
or
Select Meny → Skjerm innstill → Språk
Edited: 2016-09-05  Link: https://www.megalink.no/login/?page=faq&lang=en#how-do-i-change-the-language-on-mlshootThe problem is that the driver for the HASP dongle is not corectly installed.
- Check first that the dongle is connected to the computer.
To solve the problem try the following:
1. Remove the HASP driver in the Device manager (if you find it there)
2. Unplug the HASP dongle
3. Reboot the computer
4. Install MLShoot
5. Insert the HASP dongle and start MLShoot
When the event database grows, the software can start to respond slowly. It’s therefore recommended to clean the database before new events.
Do the following:
NB: This will delete all old events. But the old database is backup-ed to the folder MLBiaDbackup.
Edited: 2016-03-08  Link: https://www.megalink.no/login/?page=faq&lang=en#software-working-slowlyAPI for getting latest software bundle version and date:
http://www.megalink.no/login/api.php?c=get_sw
Returns JSON
Edited: 2017-02-03  Link: https://www.megalink.no/login/?page=faq&lang=en#api-get-latest-software-bundle-version-and-date